EXSOLAR
  • Home
  • About
    • Meet The Team
    • Digital Signage
    • ExSolar Electrical Services
    • FAQ
  • Systems
    • Custom Solar Quote
    • Installations Gallery
    • Backup Systems
    • Grid Tied Systems
    • Camping & 4x4 kits
  • Products
    • Inverters >
      • Portable Power
      • Victron Inverters
      • Hybrid Inverters
      • Fronius Inverters
    • Batteries >
      • Freedom Won LiFePO4
      • Solar MD Li-Ion
      • Deye LFP
      • Sinotec LiFePO4
      • Lead Calcium Batteries
    • Battery Products >
      • Battery Monitors
      • Battery Management Systems
      • Isolators and Combiners
      • Battery Protect
      • DC-DC Converters
      • DC-DC Chargers
    • Panels >
      • Poly Panels
      • Mono Panels
    • Allbro Electrical
    • Chargers & Charge Controllers >
      • Solar Charge Controllers
      • Chargers
    • Victron Accessories
    • Cables
    • System Monitoring
    • Storage Solutions
    • Mounting Structures
  • Energy Efficiency
    • Heat Pumps
    • PowerTrim
    • Smart Energy Monitor | PiMx
  • Specials
  • Blog
  • Contact Us
    • Training
    • Technical and Installation Support
    • Repairs Returns Policy
  • Home
  • About
    • Meet The Team
    • Digital Signage
    • ExSolar Electrical Services
    • FAQ
  • Systems
    • Custom Solar Quote
    • Installations Gallery
    • Backup Systems
    • Grid Tied Systems
    • Camping & 4x4 kits
  • Products
    • Inverters >
      • Portable Power
      • Victron Inverters
      • Hybrid Inverters
      • Fronius Inverters
    • Batteries >
      • Freedom Won LiFePO4
      • Solar MD Li-Ion
      • Deye LFP
      • Sinotec LiFePO4
      • Lead Calcium Batteries
    • Battery Products >
      • Battery Monitors
      • Battery Management Systems
      • Isolators and Combiners
      • Battery Protect
      • DC-DC Converters
      • DC-DC Chargers
    • Panels >
      • Poly Panels
      • Mono Panels
    • Allbro Electrical
    • Chargers & Charge Controllers >
      • Solar Charge Controllers
      • Chargers
    • Victron Accessories
    • Cables
    • System Monitoring
    • Storage Solutions
    • Mounting Structures
  • Energy Efficiency
    • Heat Pumps
    • PowerTrim
    • Smart Energy Monitor | PiMx
  • Specials
  • Blog
  • Contact Us
    • Training
    • Technical and Installation Support
    • Repairs Returns Policy

ExSolar Blog

Venus OS v2.23 – VE.Bus error 11 details & more

20/2/2019

0 Comments

 
Picture
Victron Energy have released version 2.23 of Venus OS – the software which is at the heart of the Color Control GX, Venus GX, Octo GX and the CANvu GX. A nice page outlining those products and comparing them is available here. They have also released VE.Bus version 455, for the MultiGrid and MultiPlus-II inverter/charger models.
Included in this update are various improvements; including that the user interface will not show details of VE.Bus Error 11.

VE.Bus Error 11
This error only applies to the MultiGrid and MultiPlus-II models: the inverter/chargers with a dual backfeed relay. For ESS systems, a grid-code is selected in VEConfigure, and then as part of grid-code compliance; the device verifies that its internal relays and measurement circuitry functions properly. When this test fails; Error 11 shows. Quite often, the error can be tracked down to an installation error (swapped Phase and Neutral wiring for example), but there were also some software issues; and the details of Error 11 not being visible was not helping. Today we are taking care of all that. A short list of related firmware releases:

  1. VE.Bus firmware 454 – February 8th – Adds detailed Error 11 reporting.
  2. Venus OS v2.23 – today – Adds detailed Error 11 reporting.
  3. VE.Bus firmware 455 – today – Fix false Error 11 of the type “AC0/AC1 mismatch” and “UMains error”.

Conclusion: if you have a VE.Bus Error 11 and have already double-checked the wiring, then update all to the firmware released today; which is likely to solve the issue. And if it doesn’t – then at least you will have far more information to help you resolve it.

Full changelog
General:
  • Fix that changing the date & time did not work properly for off-grid systems: changes to the date and time were only stored to the device when being rebooted from within the menus (which nobody ever does). Power cycling a unit would make it jump back to the previous date & time. This is now fixed. Note that only installations without internet were affected: with internet, the date and time are set automatically; as well as stored properly. This bug has always been in the system, since the first release.
  • Update Eastern Europe time zones; fixes issues with Romania and other countries
  • Add a low-cell voltage warning and alarm for Lynx Ion BMS systems. Note that this warning and alarm is only available for systems with a Lynx Ion BMS. Not for the (discontinued) Lynx Ion + Shunt models; and also not for any other (CAN-bus connected) battery types. How does it work? It will first issue a warning; and that will change to an alarm once the voltage is so low that the system has disabled the ‘allow-to-discharge’ signal; which shuts down any connected inverters and other loads.
  • Fix internet connection issues for a small number of systems; by lowering the MTU to 1450. If affected you typically see that logging data to the VRM works, but Remote Console does not work; and Remote VEConfigure and Remote Firmware Update work partially: scanning typically works; but anything using full packet sizes; such as uploading a firmware file; or transferring the VEConfigure file; does not work and returns error 1300. More information here: https://community.victronenergy.com/questions/3608/how-to-solve-error-1300-on-remote-ve-configure.html
  • Fix VE.Bus Low Battery, Overload and Temperature warnings and alarms showing up twice in the menu and notifications (bug was introduced in v2.18)
  • Fix vup-error-9 on VRM Remote Firmware system. The error in itself was harmless; but raising questions.
  • Debounce VE.Bus warnings: warnings now stay valid for at least 20 seconds in order to reduce the number of warning -> ok -> warning changes; notifications and VRM emails.
  • Add the names of various new VE.Bus inverter/chargers
ESS:
  • Fix bug in Scheduled charging that failed to make optimal use of the PV when in the scheduled charging window.
  • When Active AC input is a generator, enable the Fronius zero-feedin limiter. Thanks to Simon Hackett for reporting.
  • For systems with CAN-bus BMS batteries, MPPT Solar Chargers, and DVCC enabled, the use of PV power in systems with a relatively small batteries has been improved. An example to illustrate it: lets say the battery indicates a discharge limit of 25A. And at the same time, there is 40A of solar available from the solar charger. In the old situation; the maximum draw from the DC bus would be 25A = 1250 W. Net result for the battery would be that it was being charged with 40 – 25 = 15 Ampere. With v2.23 installed, it will allow up to 65 A draw from the DC: 25A from the battery, and 40A from the solar charger.
Venus GX:
  • Improve flexibility of the multiplier setting for the pulse counter; the spinbox has been replaced with a normal edit box where a number can be entered now; with up to 6 decimal places. (thank you Greg for helping with this)
ModbusTCP:
  • Make battery relay writeable, i.e. Lynx Shunt (thanks Shane)
  • Add registers related to charge current and temperature alarms.
  • Add register for LowCellVoltage alarm & warning sent by the Lynx BMS
  • Add register for Battery Temperature on VE.Bus devices.
  • Add register for VE.Bus system reset; same function as in the inverter/charger menu in the Device List.
And then there are a few more improvements, enhancing system stability and robustness.
For those who were hoping to find the Marine MFD chartplotter integration, as explained here in a blog, I have to disappoint you, it’s not ready yet; so not in this release. We can report good progress on that project though; and I still expect to release it at the end of this quarter for Navico and Garmin. As mentioned during the announcement, Raymarine will follow a bit later.

How to update?
You can find information about how to install the new version of Venus OS here. For the full changelog, visit Victron Professional.

​Article courtesy of Matthjis Vader at Victron Energy 
0 Comments

Your comment will be posted after it is approved.


Leave a Reply.

    Authors

    Marketing Manager for ExSolar Solar Solutions

    Archives

    May 2024
    March 2022
    February 2022
    January 2020
    May 2019
    April 2019
    March 2019
    February 2019
    January 2019
    December 2018
    November 2018
    October 2018
    August 2018
    July 2018
    April 2018
    June 2017
    April 2017
    March 2017
    December 2016
    September 2016
    June 2016
    May 2016
    April 2016
    March 2016
    January 2016
    December 2014
    November 2014
    October 2014
    September 2014
    August 2014
    May 2014
    April 2014
    February 2014
    January 2014
    May 2013
    September 2012
    July 2012
    March 2012

    GET IN TOUCH WITH US

    You are receiving this communication as a customer listed on our database. From 1 July 2021, compliance with the Protection of Personal Information Act (POPI Act) requires us to ensure that those we communicate with have opted to receive our messages and other relevant information. If you would not like to receive messages and other relevant information from us in future, please send us an email to [email protected] , requesting the removal of your details from our database.
Submit
Disclaimer: Please note that ALL pricing on the website is subject to change due to stock availability. 

Email

[email protected]

​Tel

+27 21 851 1700

Hours

Mon-Fri: 08h00 - 16h30 (Admin & Retail Shop)
Saturday : 08h00 - 13h00 (Retail Shop Only)
​Weekend and After hours enquiries to be sent via email